Connect the power cable to the terminal
block [12] as per the wiring diagram.
Install tension relief [10]. Put the terminal
block cover [4] on and screw it into place.
Hang the internal housing [3] on the top
of the connecting flange [2] and clip it into
place in the safety catch. Do not twist it.
F
With EVN 15 P fans: Insert the pull-cord
into the two housing grooves before
putting the internal housing [3] on.
Switch the mains fuse on. Carry out a
function test.
7. Maintenance
The unit is maintenance-free.
With fans in swivel windows
Check the connection cable regularly for
signs of damage at the transfer point from
the window sash to the window frame.
If the cable is damaged, have it replaced by
a trained electrician.
8. Cleaning
Danger to life! Unit is powered
up!
Switch the mains fuse off. Do
DANGER
not flood the unit with liquid.
Hold the internal housing [3] at the bottom,
on the right and left side and pulling equally
on both sides, pull it forwards and off.
Do not pull the internal housing [3] off
i
by the internal grille or the upper
edge.
Clean the internal parts with a dry cloth. If
necessary, use a vacuum cleaner. Swing
the lamella upwards to clean the external
shutter.
Do not clean use any cleaning agents
i
that are aggressive, easily
inflammable or harmful to health.
8
Fit the internal housing [3] as shown in
Figure E.
Do not clean the internal housing
in a dishwasher.

9. Fault rectification

Danger to life! Unit is powered
up!
Switch the mains fuse off. Do
DANGER
not flood the unit with liquid.
A fault can occur if, for example, the
airstream temperature increases or if the fan
motor is blocked. The overload protection
kicks in and the fan switches off.
If the fan fails to operate, always check
whether the mains fuse is switched on. If
necessary, have the cabling checked by an
expert. To do this, the unit must be
completely disconnected from the power
supply.
Let the fan motor cool down. After that, the
fan switches back on automatically
(thermal switch automatically resets).
If the fault still continues or occurs again,
switch off at the main fuse and call on the
services of a trained electrician.
10. Disposal
Not in domestic waste !
i
The unit contains in part material that
can be recycled and in part
substances that should not end up as
domestic waste.
Dispose of the unit once it has reached the
end of its working life according to the
regulations valid where you are.