UK | 6 Settings main menu
Room sensor configuration
Parameter
Room sensor
configuration
The temperature determined with the selected
room sensor is used as the room temperature
to control the bypass and any supplementary
heating connected.
Factory setting
Parameter
Factory setting
Reset customer level: Owner and tenant set-
tings are reset to the factory setting. Installer
settings at installer level are retained.
Reset customer & installer level:
Factory setting is restored (complete reset).
Comfort control unit (touchscreen control
unit)
Parameter
Comfort control unit
When commissioning with comfort
i
control unit briefly connected
1. Connect comfort control unit to the con-
trolled domestic ventilation control (circuit
board A2) in accordance with installation
instructions and switch on.
2. Select this parameter and activate the
interface with "yes".
3. When commissioning is complete, deacti-
vate the interface with "no", otherwise
operation is undefined.
4. Lastly, remove the connection to the con-
trolled domestic ventilation control.
62
Setting
Control unit (comfort
control unit), external,
internal, bus
Setting
Reset
customer level
Reset customer &
installer level
Setting
no: Interface for
comfort control unit
deactivated
yes: Interface for
comfort control unit
activated
ModBus
Setting
only possible with commissioning
i
software or web server.
Parameter
ModBus
Simple control unit
Solo mode only
i
control unit is connected. Function not
available with
tool.
Parameter
Simple control unit
Solo: Ventilation unit is operated with simple
control unit supplied + maximum of 4 optional
simple control units.
Auxiliary: Ventilation unit is operated with one
optional comfort control unit + maximum of
5 optional simple control units.
Inactive: The connections are needed for
extra sensors (sensor 3 and 4). Function only
if no simple control unit is connected.
Digital: A 3-stage simple GLT circuit (e.g.
KNX) can be created via an actuator for
ventilation level adjustment  wiring diagram
in installation instructions, Chapter 19.
Setting
no / yes:
For detailed info
 download area at
www.maico-ventila-
toren.com.
possible if no comfort
app or
web
Setting
Solo
Auxiliary
Inactive
Digital