IMPORTANT!
This cooktop must be grounded.
Always disconnect electric supply cord from the
wall outlet or service disconnect before servicing
this appliance.
Observe all governing codes and ordinances
when grounding, in absence of which, observe
National Electrical Code ANSI / NFPA No. 70.
The electrical supply must be a correctly polarized, grounded 120 V AC, 60 Hz, single phase circuit suitable for the maximum current draw of the
model, as detailed in the table below. Please verify your model's current draw by checking the rating label on the cooktop.
MODEL
MAX. CURRENT DRAW
CPV2-30" models
15 A
CPV2-36" models
15 A
CPV2-48" models
15 A
Required grounding method
This appliance is factory equipped with a power supply cord with a three-prong grounding plug (with polarized parallel blades). It must be plugged
into a mating grounding type receptacle, connected to a correctly polarized 120 Volt circuit. If the circuit does not have a grounding type receptacle,
it is the responsibility and obligation of the installer to have the existing receptacle changed to a properly grounded and polarized receptacle in
accordance with all applicable local codes and ordinances by a qualified electrician. In the absence of local codes and ordinances, the receptacle
replacement shall be in accordance with the National Electrical Code.
IMPORTANT!
The third prong should not, under ANY circumstances, be cut or removed.
9
ELECTRICAL CONNECTION
CIRCUIT
15 A
15 A
15 A
The rating label is located
A wiring diagram
on the right-hand side of the
label is attached
cooktop, towards the front.
to the bottom of
the cooktop
Receptacle Box
Cover Plate
Three
Prong
Plug
Three Prong
Receptacle
11