TIME ADJUSTMENTS
the times of this electronic board/panel can only be adjusted when the gate is closed.
If the trimmers are adjusted at half stroke or when the gate is open, the microprocessor will wait until it closes (at the end of the cycle) before
starting the newly set times going.
PUSH-BUTTON PANEL WITH 12V LIGHT LED FOR SIGNALLING THE GATE IS OPEN (MAX. POWER 6W)
Connect the light between terminal 8 and terminal SL.
230V FLASHING LIGHT
Connect the flashing light to terminals L-L.
If the safety devices intervene during movement, the flashing light continues operating.
SAFETY DEVICE (RADIO-PNEUMATIC-MECHANICAL STRIPS OR PHOTOSTRIP)
Safety device connections depend on the how they are arranged on the system.
Should you wish to protect the gate's range of action whilst it is opening, we advise you to connect the strips to terminals 8-2.
In this case, if the strip is operated, the automation will stop.
If you wish to protect the gate's range of action whilst it is closing, the best idea is to connect the strips to terminals 8-B.
In this case, if the strip is operated, the automation will move in the opposite direction.
LIMIT SWITCHES
If electro-mechanical limitswitches are used, connect them to terminals 8-4 to stop opening and 8-7 to stop closing.
If the limitswitches are not used, the relative terminals must be connected to the common terminal n°8.
SETTING THE CONTROL PANEL
once all the connections have been made as in the diagram, it is a good idea to follow the following method to prevent any faulty manoeuvres:
A
- Put the automatism in quiescent conditions (with the motoriductor released).
B
- Check that power relays K1 and K2 are excited when the opening push-button (8-9) is pressed, and that the motors revolve in the
opening direction (if necessary, invert wires V and W leaving the connections of wire C on the motor which revolves in the opposite
direction unaltered).
C
- Check that the first leaf is commanded to close by the motor connected between terminals V2-C-W2.
the delay before the second motor starts the closing process can be adjusted with trimmer R3 (max. 30").
D
- Adjust the operation timer using trimmer R2 so as to let the reduction gear clutch slide for 2-3 secs during opening.
the operation timer is fed during the whole opening phase and during closing, after it has had the consent from the second leaf delay
timer.
When there is only one motor connected, put trimmer R3 in the minimum count position, and the motor clutch will slide for a second
longer during closing than during opening.
n.B.: IF onLY onE MotoR IS ConnECtED, ConnECt to "M1".
n.B.: It IS oBLIGAtoRY to EARtH tHE CEntRAL UnIt (CEI REGULAtIonS 61-1).
TECHNICAL SPECIFICATIONS:
- temperature range
- Humidity
- Supply voltage
- Frequency
- Maximum consumption of card (excluding motors, lamps and external actuators)
- transient mains power drops
- Maximum power at motor output shaft
- Max. load at flasher output
- Available current at photocell power output
- Radio receiver connector with power supply
- Electrical protection
- Weight of equipment
- Dimensions
- Volume
- All inputs must be used as clean contacts because the power supply is generated on the card and is arranged so as to ensure double or
reinforced insulation with respect to live parts.
- All inputs (function - safety) are controlled by a programmable integrated circuit (PAL).
from 0 to 70°C
< 95% without condensation
230V~ ± 10%
50/60 Hz
38 mA
20 mS
1 Hp
40W 250V cos = 1
0.8A 24Vac ±15%
0.8A 24Vac ±15%
IP 54
2 Kg
20.5x24x10.5 cm
5166 cm
3