PLUG J2
Fn
- 230V ±10% 50/60 Hz power supply.
- Earth terminal.
M1
- Monophase motor (C common wire- V1/W1 - Inverters).
M2
- Monophase motor (C common wire- W2/V2 - Inverters).
L-L
- 230V electronic flashing light feed output.
PLUG J3
8
- Common contact (3 terminals available).
B
- Safety strips contact during closing (n.c.).
10
- Photo cells contact (n.c.).
9
- opens push-button (n.o.).
11
- Closes push-button (n.o.).
4
- Limitswitch connection for end opening (n.c.).
7
- Limitswitch connection for end closing (n.c.).
K
- Single pulse contact (n.o.).
2
- Stop push-button (n.c.).
PLUG J4
A*
- Common wire for power supply.
D
- 12Vac power supply for accesssories.
SL
- Gate open light LED power supply.
1
- 12Vac electric lock power supply.
A
- 24Vac power supply for photo cells.
CONNECTOR J5
Connector for housing R.I.B. radio receivers.
FUSES
F1
- Fuse 5A 250V.
F2
- Fuse 2A 250V.
PLUG "ANTENNA"
Plug to connect the aerial's shielded cable (type RG58-52).
the central wire must be fixed in the clamp with cut screw, and the cable with the external copper braiding must be fixed in
the clamp with cross screw.
notE: Be sure that the central wire of the cable does not enter in contact with the external copper braiding because this would prevent the
functioning of the aerial.
PUSH-BUTTONS AND SELECTORS
Should there be two or more push-button panels, connect the open and close controls (terminals 9 and 11) in parallel between them/with one
another and the stop contacts (terminal 2) in series between them/with one another.
Any key selectors must be connected between terminals 8-9-11
If no stop push-buttons are scheduled, make a bridge between terminals 2 and 8.
PHOTO CELLS
the photo cells (inserted as in the figure) make it possible to interrupt the movement of the automatism both in the opening and in the closing phase
(with movement being reset at the end of the intervention).
Should the photo cells be damaged, if you give a gate movement command, the flashing light will not signal and the motors will remain stationary.
n.B.: If two or more pairs of photo cells are connected, connect the A*-A power supply to all the transmitters and receivers in parallel and connect
terminals 8-10 in series with one another (n.c.).
RADIO
By making the contact given by the radio receiver relay (operating plug J5 between terminals 1-2), the gate is opened (if it is closed or in any
position except at the end of the opening cycle) and closed (when the operation timer has finished counting the opening time).
If the gate is moving and you intervene with the radio control, the first pulse you give will be Stop and the second will be consent for movement in
the opposite direction to the one it was moving in before it was stopped.
AUTOMATIC CLOSURE
the automatism closes automatically after the time set on trimmer R1 and can be disconnected opening the jumper W2.
n.B.: Automatic closing is automatically connected when the operation timer (R2 ) has finished counting.
When the gate is open, every time you go in front of the photo cells, the automatic closing timer starts counting from the beginning again.
In case of power failure fail when the gate is open, automatic closing is deactivated.