Languages; Incidents - Ingeteam INGEREV CITY CW116 Manuel D'installation Et Usage

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Ingeteam
In the event that the station is in the awaiting vehicle status and the electricity supply is lost, the message shown
is:
If the supply loss occurs when a vehicle is being charged, the message is:
In this situation the user must identify the ID card using the reader again and select the socket being used to
unlock the cover and be able to disconnect the vehicle. After this process, the station turns off if the other socket
is not being used.
A Master User can unlock the cover to pull out the connector and, after identifying themselves, can
shut down the station with the lock active, as long as the sockets are being used.
When supply is restored after the supply is lost, the station returns to the status active before said loss of supply.

9.3. Languages

The information of each user session is displayed in the language configured on each card, regardless of the
default language configured in the station.
The station operator can change the configured default language of the station using a Master card.
In the case of users with no language configured, the station displays the information in the default language set.

9.4. Incidents

In the event of incidents the station switches to incident status, indicating the incident on the display.
Fault in the installation (error code 0001)
The station protections have tripped.
The station detects that the fault persists in the installation and the protections will not be restored until the fault
disappears.
The electrical installation must be checked by qualified personnel.
Interrupted supply (error code 0002)
Absence of electricity grid. There is no electricity supply. The station restarts when it is restored.
The protections have tripped. The protections have tripped but the fault causing the trip has disappeared.
In the case that unit has resettable protections, the station will reset the protections shortly.
Incorrect hatch position (error code 0004)
The hatch is not in the position corresponding to the charge status.
Make sure that there are no loose or incorrectly inserted cables in the control card.
Connector powered (error code 0008)
The connector has power when it shouldn´t or it didn´t have it when it should.
Inform the technical service of the incident.
Energy meter communication fault (error code 0016)
The internal communication with the energy meter is not correct, possibly due to a trip of the protections. Proceed
to check the electric installation with a qualified personnel to check if protections have tripped.
If the protections have not tripped, notify the incident to the technical service.
RFID communication fault (error code 0032)
There is an anomaly with the internal communication with the card reader.
Inform the technical service of the incident.
54
"AC FAILURE"
"AC FAILURE. Identify again to unlock the door"
ABA2020IQM01_A - Installation and Operation Manual
Operation

Publicité

Table des Matières
loading

Table des Matières