Ingeteam
Pedestal
1.
Install the pedestal in the ground using four threaded components. Fasten the joint using nuts and
washers. If you wish to add the bottom trim it should be installed in the ground before the pedestal.
2.
Install the charging station on the pedestal. Fasten the joint using nuts and washers.
7.3.3. Connecting the power to the unit
Cabling requirements
The connection must meet certain requirements:
Connection specifications
Connection type
Number of conductors
Rated current
Conductor maximum diameter
32
Single phase
2P + E
up to 32 A
10 mm
(2 x 6 mm
2
ABA2020IQM01_A - Installation and Operation Manual
Installing and connecting the unit
Three phase
3P + N + E
up to 32 A
)
2