Aventics SERCOS III Mode D'emploi page 74

Masquer les pouces Voir aussi pour SERCOS III:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 91
74
AVENTICS | SERCOS III | R412012610–BDL–001–AB
Commissioning and Operation
Table 10:
Examples for assignment of switches and valve supply, 32 valve coils
S2.1
0
A0.0
A0.1
A0.2
A0.3
A0.4
A0.5
A0.6
A0.7
S2.2
1
A1.0
A1.1
A1.2
A1.3
A1.4
A1.5
A1.6
A1.7
S2.3
2
A2.0
A2.1
A2.2
A2.3
A2.4
A2.5
A2.6
A2.7
S2.4
3
A3.0
A3.1
A3.2
A3.3
A3.4
A3.5
A3.6
A3.7
1)
White fields indicate valve positions with double solenoid valves.
Fields highlighted in gray indicate valve positions with single solenoid valves.
Example 1
Valve
Sol. LED
1)
position
1
14
12
2
14
12
3
14
12
4
14
12
5
14
12
6
14
12
7
14
12
8
14
12
9
14
12
10
14
12
11
14
12
12
14
12
13
14
12
14
14
12
15
14
12
16
14
12
Example 2
Subbase for double solenoid valves
Valve
1)
position
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Example 3
Valve
Sol. LED
position
14
1
14
2
14
3
14
4
14
5
14
6
14
7
14
8
14
9
14
10
14
11
14
12
14
13
14
14
14
15
14
16
Sol. LED
1)
14
12
14
12
14
12
14
12
14
12
14
14
14
14
14
12
14
12
14
14
14
12
14
12
14

Publicité