72
AVENTICS | SERCOS III | R412012610–BDL–001–AB
Commissioning and Operation
Table 9:
Assignment of the S4 switches
Slider
plate
2.1
Power supply control
2.2
Power supply control
2.3
Power supply control
2.4
Power supply control
Function
byte 1
byte 2
byte 3
byte 4
How to assign the valve supply:
1. Open screw cap B (see figure on page 69).
2. Using the S4 sliding switch, assign one of the two supply
voltages U
page 71 and Table 9).
Examples for assignment of switch S2 and the supply of
assembled valves for 32 valve solenoids can be found in
Table 10 and Table 11 on pages 74 and 75 (examples 1 to 3/
examples 4 to 6, respectively). The following example
combinations are listed there:
Switch position 1
U
Q1
(external supply,
PIN 2, white)
U
Q1
(external supply,
PIN 2, white)
U
Q1
(external supply,
PIN 2, white)
U
Q1
(external supply,
PIN 2, white)
or U
to each valve group (see figure on
Q1
Q2
Switch position 2
U
Q2
(external supply,
PIN 4, black)
U
Q2
(external supply,
PIN 4, black)
U
Q2
(external supply,
PIN 4, black)
U
Q2
(external supply,
PIN 4, black)

Publicité