EN
Note: This mode is
ideal for days with high
humidity: it reduces the
appearance
of
water
particles in the grilles.
Efficiency indicator
Depending
on
operating temperature,
the
Blueface
displays
a range of colors that
reflects
the
level
efficiency of the system:
Green: very efficient.
Yellow: efficient.
Orange: inefficient.
Red: very inefficient.
7
Ventilation: In this operating mode, the system works
exclusively in ventilation mode when any of the zones is
generating demand (Setpoint T < room T).
Cooling: In this operating mode, the system works exclusively
in cooling mode when any of the zones is generating demand
(Setpoint T < room T).
Heating: In this operating mode, the system works exclusively
in heating mode when any of the zones is generating
demand (Setpoint T <room T).
Dry: In this operating mode the system works in dry mode,
refreshing the zone (reducing the humidity) when any of the
zones is generating demand (Set-point T< Room T).
Eco-Adapt saving function
levels and also adapts the temperatures to make your system
more efficient. Eco-Adapts sets limits based on the level of
efficiency:
Disabled: In this option, there are no saving limits. The
the
available temperature ranges of temperatures are the ones
allowed by the system: 15-30 ºC in heating mode and 18-30
ºC in cooling mode.
of
Manual: It sets the temperature limits of the zones according
to the temperature set in the Master thermostat.
A. It sets the saving limits for saving heat in 24 ºC to 30 ºC, for
cold between 15 and 22 ºC.
A+. It sets temperature limits to raise the level of energy
efficiency: 25-30 ºC in cooling and 15-21.5 ºC in heating.
A++. It sets limits to reach the highest level of efficiency.
Cooling: 26-30 ºC; heating: 15-21 ºC.
It offers several energy efficiency