Flow rate max. (100% water)
Service
Accuracy up to 15 PSID = 100
kPa
Minimum ΔP for start-up
Maximum ΔP
Maximum working pressure
Close off pressure
Temperature
Connection
Leakage
VA-7482-8002-RA Actuator
The following table describes the VA-7482-8002-RA technical specifications.
Power requirements
Input signal
Input signal adjustments
Input impedance
Electrical connections
Mechanical connections
Protection
Output force
Mechanical stroke
Full Stroke Cycle Time
Full Stroke Cycles
Audible Noise Rating
Fluid Temperature Limits
Ambient Operating Conditions
Ambient Storage Conditions
Compliance
United States
Canada
Europe
The performance specifications are nominal and conform to acceptable industry standard. For application at conditions
beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages
resulting from misapplication or misuse of its products.
Table 3: VP140 Cxx
VP140CAU
9.7 GPM, 2,200 l/h
3.6 psi
25 kPa
1" FNPT
Johnson Controls, Inc., declares that this product is in compliance with the essential requirements and other relevant provisions of the
PED (Pressure Equipment Directive).
24 VAC ±15% at 50/60 Hz; 24 VDC ± 15% at 2.5 at maximum
power supply, Class 2
0 to 10 VDC or 0 to 20 mA
Input Signal: 0 to 10 VDC, 2 to 10 VDC, 0 to 5 VDC, 5 to 10 VDC
100,000 ohms
18 AWG cable; 59" (1.5 m) long
M30x1.5
NEMA 2, IP43
31.4 lb (140 N) Minimum)
0.25 in. (6.3mm) Maximum
8 s/mm
150,000
<30 dBA
35 to 203 °F (2 to 95 °C)
32 to 122 °F (0 to 50 °C), Non condensing, 90% RH
-4 to 149 °F (-20 to 65 °C), Non condensing, 95% RH
Tested per UL2043. Suitable for Use in Other Environmental Air
Space (Plenums) in Accordance with Section 300.22 (C) of the
National Electrical Code.
UL 60730-1 Listed Type 2 Enclosure - File E194024 XAPX,
XAPX7
CAN/CSA E60730-1:02
Johnson Controls, Inc., declares that this product is in
compliance with the essential
requirements and other relevant provisions of the EMC Directive
and Low Voltage Directive
VP140CAW
11.9 GPM, 2,700 l/h
Water or water-glycol mixture (up to 50% glycol), quality to VDI 2035
± 5%
4.4 psi
30 kPa
87 psi
600 kPa
362 psi
2495 kPa
100 psi
689 kPa
14 to 248 °F
-10 to 120 °C
ANSI Class IV IEC 60534-4
18
VP140DAW
11.9 GPM, 2,700 l/h
4.4 psi
30 kPa
1 1/4" FNPT Union
P/N 14-88360-03389, Rev.A
VP140DAY
13.2 GPM, 3,000 l/h
5.1 psi
35 kPa