Assembly
Installing the lifting column at the interfaces > Assembling the external profile - Multilift II

5.4.3 Assembling the external profile - Multilift II

Positioning the lifting column
Fastening the lifting column
106
RK Rose+Krieger GmbH recommends that the lifting
column be fastened to the supporting/contact surface
on the motor side.
Personal:
Schutzausrüstung:
Prerequisite:
n
The substrate (e.g. metal plate screwing surface or foot) has
been prepared for fastening the lifting column.
1.
Place the external profile of the lifting column on the sub-
strate, and position it.
The supporting surface of the lifting column must
rest fully on a metal plate of at least 5 mm in
thickness.
Fig. 30: Connection points
A Multilift II Standard/ESD/impact/clean
B Multilift II telescope/telescope ESD
2.
Insert 2 screws into the drilled holes (Fig. 30/1) on the base
plate of the lifting column and the substrate.
Lifting column Multilift I/Multilift II
n
Assembly staff
n
Protective clothing
n
Protective gloves
n
Safety shoes
20.02.2019