Network Connection - Burda PEFRECTCLIME RELAX DARK IRC IP55 Notice D'installation Et D'utilisation

Masquer les pouces Voir aussi pour PEFRECTCLIME RELAX DARK IRC IP55:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

GB

NETWORK CONNECTION:

• An overvoltage category III Combined
Circuit breaker and Residual Current Device
(RCD) with rated earth leakage operation not
exceeding 30mA must be fitted upstream on
the supply line in order to have a contact
separation in all poles that provide a full
disconnection. The circuit breaker must have
a contact opening distance of at least 3 mm.
• The product is in class I and IP55, which
is the protection rate for the units to be used
even outdoor. For keeping the protection rate
of the appliance, the connection of the appli-
ance with the power supply must be done by
means of a minimum IP55 system, as per the
standards HD 384 CENELEC for Europe, or
international IEC 60364-7 1988.
WARNING:
The radiator must never be installed in the up-
ward or inward position, the heating surface
must always be positioned so that the heat is
directed downwards or outwards.
The heater must never be installed in the up-
ward or inward position, the heating surface
must always be positioned so that the heat is
directed downwards or outwards.

Publicité

Table des Matières
loading

Table des Matières