ERROR LOGIC & TROUBLESHOOTING continued

Motor Error2

Occurs when the platen is in motion
and fails to reach the upper or lower
limit position within 30 seconds,
(150 encoder counts)
L1: MOTOR
L2: ERROR2
Audio Alarm
Recycle Main
Power Switch
Part # 4517124 Rev. 7 (08/17/11)

Lower Switch Error

Occurs at cycle start when the
lower limit switch fails to signal the
platen's arrival at the lower limit
position within 200 seconds.
L1: LOWER SWITCH
L2: FAIL
Audio Alarm
Recycle Main
Power Switch

Upper Switch Error

Appears in code,
but is never set.
L1: UPPER SWITCH
L2: FAIL
Audio Alarm
Recycle Main
Power Switch