CONNECTIONS
Connection with the mains
The electric connection must only be carried out by a qualified electrician!
In order to connect the device to the mains, you have to install a power cable and a power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
Connect the device to the mains with the power-plug.
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
Outputs
Output is via 4 IEC output-sockets on the rearpanel.
Connect your loads via the output-sockets. The maximum load per channel is 920 W (resistive) or 460 W
(inductive). Please note that the maximum current (depending on the power-cord and power-plug) must
never be exceeded.
CLEANING AND MAINTENANCE
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
If the fuse interrupts, please reset the breaker.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device will be damaged, it has to be replaced by authorized dealers only in
order to avoid hazards.
If defective, please dispose of the unusable device in accordance with the current legal regulations.
Should you have further questions, please contact your dealer.