Mounting
The ÉPIX™ Tile 2.0 can be mounted at any orientation, individually or in
combination with other ÉPIX™ products. The ÉPIX™ Tile 2.0 has an
adjustable mounting bracket with 13 mm holes, which are suitable for a
clamp. The housing has connection slots on all four sides for connecting
the tiles to each other and other ÉPIX™ products.
A single ÉPIX™ Tile 2.0 can hold only the following number of products
attached with the connectors and connection slots:
·
2 - ÉPIX™ Tile 2.0, or
·
1 - ÉPIX™ Bar 2.0, or
·
3 - ÉPIX™ Strip 2.0
When attaching multiple ÉPIX™ products with the connectors and
connection slots, link the safety cables so that each product is separately
attached via safety cables to the mounting structure. See
Diagram.
Each connection slot has a small round depression just in from the edge of
the tile. The connector lock knob twists a bolt into this depression to
secure the tiles together.
The tile connector wing nut loosens and tightens the connector. Loosen it
to slide the connector into the connecting tile. Then tighten it in place after
the connector is locked into place with the lock knob.
·
Make sure the mounting structure or surface, and the mounting
clamp, can support the product's weight. See
Weight.
·
Make sure the product and its cables are clear of people as well
as all other objects and cables.
·
Always use a safety cable for each individual product.
·
Do not secure a product to another product with a safety cable!
Always secure to the mounting point.
Most video software customizes the output image to appear on the
tiles in any configuration so the tiles can be hung as needed and still
display the image properly.