Troubleshooting

Fault
Appliance has no cooling capacity.
The interior light does not function.
The display does not come on.
The refrigerating unit switches on
more and more frequently and for
longer.
The temperature in the refrigerator
compartment is too cold.
The interior light does not function.
The appliance is giving off odors.

Changing the bulb

m
WARNING
To avoid electrical shock which can cause death or
severe personal injury, disconnect power to appliance
before making repairs. After making repairs, reconnect
power.
Switch off the appliance with the POWER button
Pull out the mains plug or switch off the fuse.
m
CAUTION
Never touch a halogen bulb with bare fingers.
When inserting a glass halogen bulb, always hold with
a soft cloth.
All manuals and user guides at all-guides.com
Possible cause
Power failure; the fuse has actuated;
the mains plug is not in properly.
Appliance door opened frequently.
Large quantities of fresh food placed
in the appliance.
The ventilation openings are covered.
Temperature has been set too low.
The bulb is defective.
The light switch is sticking.
Strong-smelling foods have not been
packed in airtight containers.
m
O
!
m
Remedial action
Check that the power is on. The fuse
must be switched on. Check that the
mains plug is plugged in.
Do not open the door unnecessarily.
Switch on Fast cooling function.
Remove obstacles and dirt.
Set a warmer temperature
(see "Setting the temperature").
Change the bulb (see "Changing the
bulb").
Check whether it can be moved.
Clean the appliance. Pack strong-
smelling foods in airtight containers
(see "Odors").

Halogen bulbs above

Halogen bulb type: 20 W/12 V/socket G4
Release the cover and remove from the clip.
Pull out the defective halogen bulb.
21