7. USAgE
Note :
- The massage system will stop automatically after 30 minutes of operation. Re-activate
the massage function by pressing the massage button again.
- When filter button is on, pressing bubble button will exchange filter mode into massage
mode: filter indicator light will turn off and massage indicator light turn on.
Press the heater button to activate water filtering and heating system. The red indicator
light will turn on.
The pump does not stop heating until the current water temperature reaches the set tem-
perature; and the heating system will restart after the current water temperature drops 2°C
below the set temperature automatically.
Maximum heating temperature: 42°C (108°F)
Important :
When the filtering system has worked 150 hours accumulatively, buzzing will warn
to remind you to clean the filter. You can hold the filtering button 5 seconds to turn
off the buzzing. The heating system will turn off, you can press the button to active
the heating system again.
Note :
- The heating system is dependent on the filtration system and it can't operate without.
- If the massage function is active, the filtration and heating functions can be activated.
The LED light button activates the spa lighting. Press once to turn on the lighting, each
time the button is pressed changes the color of the lighting. Press and hold to turn off the
light.
43