Contact with SMS 40

SMS commands

SMS 40 sends an SMS in the event of a power cut, when the heat pump/indoor module starts after a power cut and
in the event of a constant alarm. These messages are only sent to the alarm recipient (menu 4.1.4, menu 5.3.5 if your
heat pump/indoor module has software version 2041 or earlier).
SMS 40 can receive and send the following commands to the heat pump/indoor module:
Command
?status
?comp
?compm/?comps1
– ?comps8
?acomp
?temp
16
Answer
opmode: auto/add. heat only
reg1: -10-+10
reg2: -10-+10
reg3: -10-+10
reg4: -10-+10
roomt1: 5-30
roomt2: 5-30
roomt3: 5-30
roomt4: 5-30
tluxhw: on/off
vent: 0/1/2/3/4
hol: on/off
status: runs/off
number of starts: nn
total operating time: nn
- of which hot water: nn
status: runs/off
number of starts: nn
total operating time: nn
- of which hot water: nn
heating: nn
hot water: nn
pool: nn
pool 2: nn
flow: nn
return: nn
outd: nn
indoor: nn
calcf:nn
DM: nn
Bin: nn
Bout: nn
Description
Operating status
Temperature (offsetting the heat curve in systems without room sensors)
Temperature (offsetting heat curve in systems without room sensor),
1)
climate systems 2
Temperature (offsetting heat curve in systems without room sensor),
1)
climate systems 3
Temperature (offsetting heat curve in systems without room sensor),
1)
climate systems 4
Temperature (setting the room temperature in systems with room
sensors)
Temperature (setting the room temperature in systems with room
1)
sensors), climate system 2
Temperature (setting the room temperature in systems with room
1)
sensors), climate system 3
Temperature (setting the room temperature in systems with room
1)
sensors), climate system 4
Temporary lux (hot water)
Fan speed. 0 = normal fan speed
Holiday setting
2), 3)
Compressor status
Number of compressor starts
Total run time compressor and immersion heater?
2), 3)
Total run time hot water
Compressor status per cooling module (EP14 respectively EP15)
Compressor status =through outdoor section (EB10X)
Number of compressor starts per cooling module (EP14 respectively
4), 7)
EP15)
Total run time, compressor per cooling module (EP14 respectively EP15)
7)
Total run time, hot water per cooling module (EP14 respectively EP15)
7)
Number of compressors that produce heat
Number of compressors that charge hot water
Number of compressors that charge pool 1
Number of compressors that charge pool 2
Supply temperature
Return temp
Outdoor temperature
Indoor temperature. If the room temperature sensor is not installed/ac-
tivated, the following appears -
Calculated flow line temperature
Degree minutes
Incoming brine temperature
Outgoing brine temperature
2), 3+1), 4+1)
2), 3)
2), 3)
7)
4), 7)
4), 7)
4+1), 7+1)
4+1), 7+1)
3), 4)
3), 4)
4)
4),
4),