Display Problems - Midtronics inCHARGE 940 INC-940 Manuel D'instructions

La station de chargement diagnostique par conductance pour l'analyse et la charge des batteries automobiles de 12 volts
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Message
SYSTEM NOISE DETECTED
ARE CLAMPS CONNECTED?
Display alternates between
CONNECT CLAMPS
and
CHOOSE CHARGE MODE
when you press ENTER.

DISPLAY PROBLEMS

Problem
No display
Wrong language
Incorrect time or date
Solution
The inCHARGE940 has detected signal noise that can affect
the battery analysis.
Make sure all vehicle loads are off and the ignition is in
the OFF position.
You may be testing too close to a noise source, i.e., a
charger or other high-current device. If so, move away
and retest.
If no noise source is identified, fully charge the battery
and retest. If the message appears after recharging,
replace the battery.
CAUTION: Before charging, make sure that the clamps are
connected to the battery. Charging in Manual mode without
the clamps connected to a battery may cause sparks, fire, or
personal injury.
If the clamps are properly connected, use a voltmeter to check the
battery voltage. The inCHARGE940 requires a minimum of 1 volt to
function in Automatic mode. To raise the voltage level, charge using
Manual mode for at least 30 minutes, then abort and charge in
Automatic mode.
Solution
Make sure that the inCHARGE940 is plugged in and the outlet is pro-
viding current. The inCHARGE940 requires a 115-volt (nominal),
15-ampere circuit to operate. If the same outlet is powering other de-
vices with the inCHARGE940, a circuit breaker may trip. If troubleshoot-
ing does not correct the problem, call 1-800-776-1995 for service. For
more information, see "Patents, Limited Warranty, Service."
You can change the language (English, French, or Spanish)
in the Options menu. (See "Language" in the "Options
Menu" section.)
You can change the clock time in the Options menu. See "Set Time"
in the "Options Menu" section.
The date cannot be set outside of the initial setup. If the date is
incorrect, you must return the inCHARGE940 to Midtronics to have it
reset. Call 1-800-776-1995 to arrange for service. For more
information, see "Patents, Limited Warranty, Service."
- 16 -