If you select MANUAL:
NOTE: A test code is unavailable if you charge the battery using Manual mode.
!
a)
Select the time required to charge the battery (in half-hour increments from 0.5
to 10 hours).
b)
Select the rating system (Table 1).
c)
Select the battery rating (Table 1). The inCHARGE940 will begin charging the
battery for the selected length of time.
6.
CHOOSE TEST: Select IN VEHICLE or OUT OF VEHICLE.
NOTE: It is recommended to remove the battery from the vehicle before charging to avoid
damage to the vehicle electrical system and to charge in the chamber whenever possible.
7.
BATTERY TYPE: Select REGULAR or SPECIAL (AGM).
8.
CHOOSE TEST TYPE: Select WARRANTY, 48-HOUR CHECK, or OTHER.
If WARRANTY or 48-HOUR CHECK:
Select the battery DIN rating value (Table 1). (If the battery's DIN rating is unavailable,
select OTHER.)
If OTHER:
a)
b)
9.
The inCHARGE940 will test the battery and display one of three results in Table 2 (with the
approximate charge time, if required).
Table 1: inCHARGE940 Battery Rating Systems and Value Ranges
Rating
Description
System
DIN
Deutsche Industrie-Norm
EN
Europa-Norm
IEC
International Electrotechnical Commission
SAE
European labeling of CCA
CCA
Cold Cranking Amps, as specified by SAE. The most common
rating for cranking batteries at 0 ºF (–18 ºC).
Japanese Industrial Standard: (shown on a battery as a
JIS
combination of numbers and letters, for example: 80D26)
CAUTON: Before charging, make sure that the clamps are connected
to the battery. Charging in Manual mode without the clamps connected to
a battery may cause sparks, fire, or personal injury.
Select a rating system (Table 1).
Select the battery rating (Table 1).
- 11 -
Value Range
100 to 1000 A
100 to 1700 A
100 to 1000 A
100 to 1700 A
100 to 1700 A
43 values from
26A17 to 245H52