BATTERY ANALYSIS RESULTS
For error messages, see "Troubleshooting."
NOTE: To abort the charge session, press STOP.
Result
GOOD BATTERY
CHARGING REQUIRED
REPLACE BATTERY
TEMPERATURE
Battery temperature is critical during charging. If the inCHARGE940 detects that the temperature
has risen too high or that the battery is frozen, the charging session will stop. See "Error Messages"
in the "Troubleshooting" section for more information.
CHARGE COMPLETION AND FINAL ANALYSIS
When charging is finished, the inCHARGE940 will display GOOD BATTERY or REPLACE
BATTERY and the total charge time.
INFORMATION MENU
When the inCHARGE940 displays the final result (GOOD BATTERY, REPLACE BATTERY) three
information options are available:
•
GENERATE TEST CODE (available only after a completed Automatic charge).
•
PRINT LAST TEST RESULTS
•
VIEW LAST TEST RESULTS
To access the Information menu, leave the clamps connected and press the INFO ( i ) button while
the final battery result is displayed. Press the ARROW buttons to display an option, then press
ENTER to select.
If you turn off the inCHARGE940 or disconnect the clamps, the inCHARGE940 will save the last
test results in memory for viewing or printing until you start a new battery analysis/charging session.
(The option to generate a test code will be unavailable.) To access the Information menu before the
next session, press the INFO ( i ) button when the message CHOOSE CHARGE MODE appears.
Table 2: Battery Analysis Results and Explanations
Explanation
Analysis finds the battery to be good. Reinstall the battery.
Analysis finds that the battery has a low state of charge.
The inCHARGE940 will display an approximate charge time and
begin fast charging. The accumulated CCA and remaining
charging time are displayed and updated at intervals.
If analysis finds the battery to be bad, it will stop charging and
display the result. Replace the battery.
- 12-