Electrical Specifications - Amprobe 38XR-A Mode D'emploi

Masquer les pouces Voir aussi pour 38XR-A:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

1.800.561.8187
potential difficulties in ensuring electromagnetic
compatibility in other environments, due to conducted
and radiated disturbances.
Caution: This equipment is not intended for use in
residential environments and may not provide adequate
protection to radio reception in such environments.

ELECTRICAL SPECIFICATIONS

(Accuracy at 23 °C ±5 °C, <75 % relative humidity)
DC VOLTS
1000 mV, 10 V, 100 V, 1000 V
Ranges
(auto/manual ranging)
Resolution
100 μV
Accuracy
±(0.25 % rdg + 5 dgts)
Input impedance 10 MΩ
Overload
1000 V dc or 750 V ac rms
protection
AC VOLTS true rms (45 Hz to 2 kHz)
1000 mV, 10 V, 100 V, 750 V
Ranges
(auto/manual ranging)
Resolution
100 μV
±(1.2 % rdg + 10 dgts) 45 Hz to 500 Hz
±(2.0 % rdg + 10 dgts) 500 Hz to 2 kHz
Accuracy
±(2.0 % rdg + 10 dgts) 45 Hz to 1 kHz
on 750 V range
±(3.0 % + 200 dgts) on 100 V,
Peak Hold
750 V range; 1000 mV, 10 V ranges
accuracy
unspecified
Crest Factor
≤ 3
Input impedance 10 MΩ
24