When
installed
bathroom, do not install the
appliance in volumes V0, V1
or V2 (see figure opposite). If
there is not enough space,
they can be installed in
volume V2.
•
Refer to the installation figures. The clearance required to install
the appliance correctly is specified in the "Installation" tab.
•
This product is intended for use at a maximum altitude of 2000 m.
•
Do not block, cover or obstruct the air inlets and outlets of the
product.
•
If the appliance is set up in a suspended ceiling or attic, or above
living space, a drain pan must be installed underneath the water
heater. A drainage device connected to the sewer system is
required.
•
The water heater must (in accordance with article 20 of EN
60335-1) be fixed to the ground using a mounting system
intended for this purpose.
•
This water heater is fitted with a thermostat with an operating
temperature of more than 60 °C at its maximum position, capable
of reducing the growth of legionella bacteria in the tank. Caution!
Above 50 °C, water could cause immediate burns. Check the
water temperature before taking a bath or shower.
in
a
V1
V2
V0
V0 = Volume 0
V1 = Volume 1
V2 = Volume 2
EN
35