Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal
pressures.
Only the battery housing with battery or power pack
supplied by Hansgrohe may be connected to the
electrical connection cable of the fittings.
A damaged connecting line must not be replaced.
The transformer may no longer be used.
The transformer and its mains plug may only be
installed or plugged in in dry interior rooms.

Installation Instructions

• The fitting must be installed, flushed and tested after
the valid norms.
• The mesh washers must be installed to protect against
incoming dirt by pipework. Incoming dirt can impair
the function and/or lead to damages on functional
parts of the fixture; HansGrohe will not be held liable
for resulting damages.
• The mixer can not used together with a continuous
flow water heater.
• The fittings must not be installed on washstands with
raised edge.
• At the start of operation, or after maintenance, func-
tion of the faucet may be delayed due to reflections
during adjustment of the operating distance. The
faucet will automatically calibrate itself. The self-cali-
bration will start after 10-15 minutes.
• During initial start-up and after servicing, air in the
fittings can cause an unattractive jet pattern. The jet
pattern is okay again after switching the jet on and off
about 15 times.
English
Electrician
The installation and test work must be performed
Electrical connection
Voltage supply: 230 V AC ± 10 % / 50 – 60 Hz /
Residual current protection system
The circuit must be protected via a ground fault
Any work may only be carried out in a de-energized
The transformer must not be installed in protection

Adjustment

This mixer has the following feature: background fade-
out with integrated range adjustment, that means the
mixer is automatically adjusted on to the local conditions
(washbasin, brightness, reflection) by the sensory
mechanism.

Battery operation

The indicator LED signals that the battery must be
changed.
Battery voltage ≤ approx. 5.5 V:
The indicator LED in the sensor window blinks when the
fitting is operated, water withdrawal continues to be
possible
Battery voltage ≤ approx. 5.3 V:
The indicator LED in the sensor window lights
continuously, water withdrawal is no longer possible, the
battery must be replaced.
Attention! After insertion of the battery, the fitting should
not be activated for approx. 30 seconds. This time is
required for self-adjustment.
Assembly see page 73
Electrical installation
by an authorized electrician under consideration of
DIN VDE 0100 part 701 / IEC 60364-7-701.
2 mA
protector (RCD / FI) with a measured differential
current of ≤ 30 mA. The proper function of this
fusing/protection must be checked at regular
intervals.
state. Here, the voltage supply must be safely
separated via the main switch or mains plugs.
zones 0, 1 or 2.