Troubleshooting; Dismounting - Abicor Binzel MFS-V2 Mode D'emploi

Masquer les pouces Voir aussi pour MFS-V2:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

MFS-V2

10 Troubleshooting

Risk of injury and machine damage when handled by unauthorized persons
Incorrect repair work and changes of the product may lead to significant injuries and machine damage.
The product warranty will be rendered invalid if the unit is handled by unauthorized persons.
• Operating, maintenance, cleaning and repair work may only be carried out by qualified personnel (in
Please observe the attached document "Warranty". In the event of any doubts and/or problems, please
contact your retailer or the manufacturer.
NOTICE
• Please also consult the operating instructions for the welding components, such as power supply,
Fault
Cause
Unit is not
• Control or component defective
ready for
• Control switch S8 is not functiong or wrong setting
operation
• M-Drive safety switch not actuated
Wire is not fed • Motor defective (master or slave)
Motor control card fault: Fault cannot be eliminated
by pressing RESET trigger.
• When the wire feed trigger is pressed again, the
motor control card shows again a fault
Tab. 14
Troubleshooting

11 Dismounting

Risk of injury due to unexpected start-up.
The following instructions must be adhered to for the entire duration of maintenance, servicing, mounting,
dismounting and repair work:
• Switch off the power supply.
• Disconnect the compressed air supply.
• Switch off the entire welding system.
• Pull the mains plug.
NOTICE
• Dismounting may only be carried out by qualified personnel (in Germany see TRBS 1203).
• Observe the information provided in the following section:
 8 Putting out of operation on page EN-17.
1 Disconnect the cable assembly from the wire feeder.
2 Remove the parts to be disconnected (changeable body, mount, CAT robot mount, torch neck).
DANGER
Germany see TRBS 1203).
compressed air line.
DANGER
Solution
• Replacement by specialized personnel
• Have skilled personnel check and adjust control switch
S8.
• Check by specialized personnel
• Switch unit to currentless state
• Change motor
• Press RESET trigger
• Replace feeding system or motor control card
• Replace feed motor or motor control card
• Wire fault in cable assembly or master drive
10 Troubleshooting
EN - 19

Publicité

Table des Matières
loading