PosiTector DPM probes:
PosiTector DPM / DPM-IR
PosiTector DPM-S
Integral Surface Temperature Sensor
Magnetic Surface Temperature Sensor
Surface
Temperature
Air Temperature &
Relative Humidity
K-Type
Connector
Surface
Temperature / IR
Probe also accepts other K-Type
Sensor
thermocouple sensors (optional)
PosiTector DPM-D
PosiTector DPM-A Anemometer
Integral Surface Temperature Sensor
Cabled probe with NPT threads
1/2" NPT
Threads
Air Temperature &
Relative Humidity
Air Temperature &
Wind
Relative Humidity
Velocity
Sintered Metal Tip
(protects sensor)

Alarm Mode

Alarm Mode
Surface
Temperature
Alarm
The PosiTector DPM can automatically alert the user when
current climatic conditions exceed pre-set values. When selected,
the Alarm icon
is displayed at the the top of the screen.
Standard models will alert the user when the surface temperature
is less than 3°C (5°F) above the dew point temperature. Enable by
selecting the tick box.
Advanced models allow the user to set up custom alarm
conditions for each reading in a dataset. When connected to WiFi,
Advanced models can also send alerts via email.