NOTES ON WORK AND PAUSE TIME PROGRAMMING
This procedure is compulsory in new installations, to ensure that the control unit memorises the manoeuvre times
and a number of parameters used for obstacle detection.
control can be used (terminal 14, fig. 15) or the radio transmitter memorised on the first channel of the receiver.
N.C. contacts must have the Led lit, and the N.O. contacts must have the Led off).
- Position the power trimmers at the centre to obtain a medium sensitivity to obstacles.
- Clear the door movement area.
TIME PROGRAMMING
The Z124 control unit offers two options for learning the travel distance:
In both modes the movement speed can be selected as required.
-
-
Normal if dipswitch 9 is set to OFF.
SEMI-AUTOMATIC PROGRAMMING
Procedure:
1) Position the door at mid-travel; see procedure in the previous paragraph.
4) After three seconds led LD1 turns on. Programming procedure activated; release PROG.
5) Press the S/S button to start the self-learning process. The door starts closing.
6) When closed completely the door stops automatically.
7) The door starts opening after a brief interval.
8) Press S/S when the door reaches the required opening position.
9) The door stops and the unit memorises the pause time.
10) If automatic closure is not enabled, press the S/S button immediately; otherwise wait for the required pause time, press the S/S button and the door starts closing.
11) Door completely closed; led LD1 turns off.
12) End of programming (the control unit sets automatically to normal operating mode).
57