FILTER REMOVAL & INSTALLATION (cont.)
Removal & Installation
of the Qwik Lock™ Filter
Filter Removal:
1. Hold the filter tabs of the Qwik Lock™
Filter (sold separately) in each hand.
2. With one thumb on the Qwik Lock™
stud, which protrudes through the
integrated filter plate, lift up on the filter
tabs while pushing down on the stud.
3. This action will cause the Filter to release
from the filter cage. Slide Filter off cage.

Filter Installation:

1. Carefully slide the Qwik Lock™ Filter
over the Filter cage and press down
on the outside edge of the Filter until
the rubber gasket on the bottom of the
Filter seats securely around the base
of the Filter cage and against the lid.
2. Align the small center hole in the top
of the Filter over the Qwik Lock™ stud
on the Filter cage. Press firmly on top
of the Filter near the stud to allow the
Filter to snap over the ball on the end
of the stud. The Filter is now attached.
NOTE: Failure to properly seat the
bottom gasket could result in debris
bypassing the Filter.
WARNING: Do not operate
without filter cage and float, as they
prevent liquid from entering the
impeller and damaging the motor.
Filter
Tabs (2)
PUSH
DOWN
Qwik-Lock
Stud
6
Integrated Filter Plate
with Center Hole
PULL
UP
Rubber Gasket at
Bottom of Filter
(cutaway view)
Filter
Cage
Power
Head
Assembly