Technical data,
CDP 45, at 27 °C
Here are the technical data for the water-heating coil, installed in a CDP 45, at 27°C:
Water temperature
Capacity
Water flow rate
Water pressure drop
Water velocity
Air flow rate
Inlet temp.
Outlet temp.
Air pressure drop
Connection tube
CDP 65, at 27 °C
Here are the technical data for the water-heating coil, installed in a CDP 65, at 27°C:
Water temperature
Capacity
Water flow rate
Water pressure drop
Water velocity
Air flow rate
Inlet temp.
Outlet temp.
Air pressure drop
Connection tube
continued
l/sec
m/sec
m³/sec
m/sec
m³/sec
°C
82/71
80/60
kW
4,51
3,67
0,09
0,04
kPa
4,75
1,14
0,7
0,31
0,14
0,14
°C
27
27
°C
53
48
Pa
2,59
2,57
mm
12
12
°C
82/71
80/60
kW
7,99
6,49
l/sec
0,17
0,07
kPa
4,36
2,34
0,71
0,31
0,21
0,21
°C
27
27
°C
58
52
Pa
2,37
2,34
mm
15
15
70/35
82/60
90/70
1,3
4,01
4,93
0,007
0,04
0,05
0,06
4,7
7,86
0,06
0,62
0,84
0,14
0,13
0,13
27
27
27
34
50
56
2,52
2,58
2,6
12
12
12
70/35
82/60
90/70
2,19
7,15
8,78
0,01
0,07
0,1
2,28
4,49
7,51
0,06
0,63
0,86
0,21
0,2
0,2
27
27
27
36
55
61
2,28
2,35
2,38
15
15
15
60/40
1,56
0,01
0,26
0,13
0,13
27
37
2,23
12
60/40
2,81
0,03
0,24
0,13
0,2
27
38
2,28
15
17