Piping Length and Elevation

Pipe Size
Capacity
GAS
(Btu/h)
mm
inch
24k
Ø15.88 5/8
Indoor unit
CAUTION
!
Capacity is based on standard length and maximum allowable length is on the basis of
reliability. Additional refrigerant must be charged after 24.6ft(7.5m).

Operation ranges

The table below indicates the temperature ranges the air conditioner can be Operated within.
Mode
Cooling
64.4°F~89.6°F(18°C~32°C)
Standard
LIQUID
Length
m(ft)
mm
inch
Ø9.52
3/8
7.5(24.6) 15(49.2)
A
B
Outdoor unit
Indoor temperature
Max.
Min
Max.
Elevation
Length
Length
Ⓑ m(ft)
Ⓐ m(ft)
Ⓐ m(ft)
-
30(98.4)
A
Indoor unit
Outdoor temperature
-0.4°F~118.4°F(-18°C~48°C)
27
Additional Refrigerant for
longer than 7.5m(24.6ft)
g/m
oz/ft
35
0.38
Outdoor unit
B