4.1 Controlling the heat pump with the LED controller
When heat pump is supplied with power, controller will display with full screen, shows that it is already
connected. If connection fails in 10 seconds, please check connections between communication cable and
control display, or replace with another control display.

Button functions:

Turns the heat pump on or off
Timer button to set timer on and timer off
Gives access to the parameter list and is used to confirm settings
To set the desired working mode: heating, cooling or auto mode
To decrease
LED display icon defitioning:
heating icon, showing heat pump is in heating mode
cooling icon, showing heat pump is in cooling mode
auto icon, showing heat pump is in auto mode
compressor icon, showing compressor status
water pump icon, showing water pump status
fan icon, showing fan status
defrost icon, showing defrost status
four way valve icon, showing four way valve status
electric heater icon, showing if external electric heater is activated or not.
electric heater running icon, showing electric heater is running or not
alarm icon, showing system alarm
fan speed icon, showing high (3), medium(2) and low(1) fan speed
key pad lock icon, showing buttons on the control display are locked.
Remark:
1. Heat pump is not equipped with electric heater internally, only provides terminal for external connection.
2. Fan speed is automatically controlled by ambient temperature, not manually.