9
9.1 Indication of the parameter values and
Press the "Mode" button. The display now shows the
parameter "Uni". (Should "Loc" be displayed, the sen-
Mode
Set
sor must be enabled. For this please refer to the infor
Enter
mation provided in paragraph 9.2). You can now view the
setting of the parameter "Uni" (see below) or select
further parameters. To select other parameters, press
the "Mode" button several times. To view the actual
parameter value, simply press the "Set" button for a
short moment.
Mode
Set
If you want to alter this value, please press the "Set"
Enter
button and hold it for 5 s until the shown value stops
fl ashing. Via the
the value.
Then press the recessed "Enter" button to save the
changed value.
Mode
Set
Enter
The new setting is consequently activated.
9.2 Locking/Unlocking (disabling/enabling)
This sensor permits inhibiting access to the menu and
programming mode.
To inhibit access, call up the RUN mode, press and hold
the "Mode" and "Set" buttons simultaneously until the
display indicates Loc.
Mode
Set
To enable access, call up the RUN mode, press and
Enter
hold the "Mode" and "Set" buttons simultaneously until
the display indicates uLoc.
Hans Turck GmbH & Co.KG • D–45466 Mülheim an der Ruhr • www.turck.com
Programming
programming
and
buttons you can now change
9
/0208