Preparations for set-up and installation
Connection of the
pressure pipes
P-SUP = supply pressure
P-OUT = measuring
distance (backpressure)
Accessories
for connection to
compressed air tubes
Electrical connection
of the sensor
Page 26
P-SUP
P-OUT
Use connection elements with G1/8 standard thread and seal outside
the thread by captive gasket (according to DIN ISO 228-1).
Suitable connection elements are available as accessories:
• G1/8 thread extension with gasket (order no. E30075).
• QS-G1/8-6 push-in air fitting for tube with ∅ 6 mm (order no.
E30076).
• QS-G1/8-8 push-in air fitting for tube with ∅ 8 mm (order no.
E30077).
Please note: For self-locking threads with a teflon layer as sealing
according to DIN 2999-1 / ISO 7-1 particles of the teflon seal could
come off and soil the airways in the unit.
The unit must only be connected by an electrician.
The national and international regulations for the installation of
electrical equipment must be observed.
Voltage supply to EN50178, SELV, PELV.
Disconnect power before connecting the unit.
Wiring:
PNP
1
BN
2
WH
4
BK
2: OUT2
3
BU
4: OUT1
Core colours of ifm sockets:
1 = BN (brown), 2 = WH (white), 3 = BU (blue), 4 = BK (black).
NPN
L +
2: OUT2
4: OUT1
L
P-OUT
1
BN
L +
2
WH
4
BK
3
BU
L