Installation of the control unit
Installation
environment
Mounting positions
Connect blocks in
series:
(Observe the notes on
page 34!)
The unit must not be installed in a sealed housing / sealed control cab-
inet (the exhaust airflow at the setting dial must be allowed to vent).
0
Pressure sensor in
vertical position
= standard mounting
position
These positions are suitable for elimination of condensation and particles in
the compressed air system.
0
These positions may yield bad results if dirt is in the compressed air supply.
They should thus be avoided.
• Open the supply pressure connections (P-sup),
• supply the compressed air,
• pass on the compressed air through the included tube connector
(series connection).
P-sup
Pressure sensor in
horizontal position,
setting dial at the
bottom
0
0
Pressure sensor in
horizontal position,
setting dial to the right
0
Page 25