Technical information (pressure sensor)
RUN
M
S
M
M
S
M
M
S
M
M
S
M
M
S
M
M
S
M
M
S
M
M
S
M
M
S
M
RUN
= Set button:
S
set values
= Mode/Enter button:
M
acknowledgement
= Mode/Enter button:
M
scrolling
Page 30
Programming in general
1
Mode/Enter Set
Mode/Enter Set
2
3
Mode/Enter Set
Change more parameters:
4
Start again with step 1.
*Decrease the value: Let the display of the parameter value move to the maxi-
mum setting value. Then the cycle starts again at the minimum setting value.
Adjustable parameters
Teach function for switch point 1 /switch point 2
When the Set button is pressed the current measured value is
displayed; when it is released the value is retained.
When the Set button is pressed again the new current measured
value is displayed;
when the Mode button is pressed it is stored as switch point.
Manual setting of witch point 1 / 2 (optional)
Upper limit value at which the output changes its switching
status. The desired value is set by pressing the buttons.
• Setting range: -800 ... +800 mbar, in steps of von 2 mbar.
• Display in mbar, PSI, kPa or inH
The hysteresis is preset (12 mbar). It is in the positive range of the
switch point, adapted to the features of the pneumatic system.
Tolerance value for switch point 1 / 2
Value by which the switch point can be shifted.
• Setting range: -150 ... +150 mbar
• in steps of 2 mbar.
• Display in mbar, PSI, kPa or inH
For explanations see page 32.
Switch functions of the switching outputs
2 switching functions can be set:
• Hno = hysteresis / normally open
• Hnc = hysteresis / normally closed
Enhanced functions
This menu item contains a submenu with additional parameters.
You can access these parameters by pressing the SET button
briefly.
Press the Mode/Enter button
several times until the respective
parameter is displayed.
Press the Set button and keep
it pressed. The current parameter
value flashes for 5 s,
then the value is increased*
(incremental by pressing briefly or
scrolling by holding pressed).
Press the Mode/Enter button
briefly (= acknowledgement).
The parameter is displayed again,
the set parameter value
becomes effective.
Finish programming:
Wait for 15 s or press the
Mode/Enter button until the current
measured value is indicated again.
O.
2
O.
2