Filling with chain oil

The blade and saw chain must
never be without oil. In case of
non-observance a high level of
wear occurs on the blade and saw
chain.
The equipment is fitted with an oiling
mechanism. As soon as the motor is run-
ning, the oil flows to the blade.
Regularly check the oil level in the in-
spection window (19) and refill with oil
in time.
Use Grizzly bio oil, which contains
additives to reduce friction and wear.
This can be ordered from our service
centre.
If Grizzly bio oil is unavailable, use
chain lubricating oil with a low propor-
tion of adhesive additives.
1. Unscrew the oil tank cap (18) and
pour the chain oil into the tank.
2. Wipe off any spilt oil and close the oil
tank cap.

Initial operation

Observe the country-specific and
local authority regulations. Do not
work during commonly accepted or
mandatory rest periods.
Before starting, check:
- The saw chain tension
- The oil level
- All nuts and screws are sitting firmly
Ensure suitable protective clothing.
Adjust the working length of the tel-
escopic handle before switching on
the equipment.
Remove the protective blade cover
only at the last minute.
Put on the shoulder strap.
Check you are standing safely.
Check your working surroundings.
Putting on the
shoulder strap
Always wear a shoulder strap
when working with the equip-
ment. Always switch off the
equipment before loosening the
shoulder strap. There is a risk of
accidents.
1. Fix the carabiner hook of the shoulder
strap (21) to the eyelet (12) on the tel-
escopic handle (10) of the equipment.
2. Put on the shoulder strap (21) (see
also picture
3. Adjust the strap length such that the
carabiner hook is at hip height.
4. In addition, you can adjust the
height of the eyelet for the shoul-
der strap (12) on the telescopic
tube (10) after loosening the Phillips
screw (12a) on the eyelet.
Adjusting the telescopic
handle
The telescopic handle (10) is infinitely
adjustable using the quick release (9)
1. Flap out the quick release (9) on the
telescopic handle (10).
2. Pull or push to adjust the length of the
telescopic handle (10).
3. Reclose the quick release (9).
).