ASSEMBLY
Before assembly, check that the product is complete and has not suffered any damage during
transport.
ASSEMBLY must be carried out by a specialised company.
See USER QUALIFICATION!
The specialised company and the operator must observe, comply with and understand all of
the following instructions in this assembly and operating manual. For the system to function
as intended, it must be installed professionally in compliance with the technical rules
applicable to the planning, construction and operation of the entire system.
Risk of injuries due to blown-out metal chips!
Metal chips may cause eye injuries.
Wear safety goggles!
Malfunctions caused by residues! Proper functioning is not guaranteed.
Visually check that there are no metal chips or other residues in the connections!
It is important that metal chips or other residues are blown out!
Install with suitable tools, if required.
Regarding screw connections, use a second spanner to brace against the connection nozzle.
Do not use unsuitable tools, such as pliers.
Product damaged through incorrect installation direction
Proper functioning is not guaranteed.
Observe the installation direction (marked on the product with an arrow
Screw connections
If connections leak, there is a danger of explosion, fire or suffocation!
Gas may escape if the product is turned.
Do not turn the product after it has been installed and the connections have been
tightened.
Tighten connections only when they are not pressurised.
Installation sequence
• Screw the outlet nozzle of the automatic or manual changeover valve
or the double shut-off block
regulator
.
• Install the pressure regulator
the support rail using screws and washers.
• Fasten the pipe supports (not included in the scope of delivery) and the
support rail to the wall vertically.
With two cylinder systems
• Connect the high pressure hoses
cylinder sides between the inlet connection of the automatic or manual
changeover valve or the double shut-off block
gas cylinder. See CONNECTIONS assembly instructions.
18 / 36
to the inlet nozzle of the pressure
with automatic changeover valve
from the operating and spare
with the valve on the
).
on
Artikel-Nr. 05 075 51 e