Manual BVS 18 ATEX E 058
Annex A
Dimension drawings and dimensions in mm
1
Technical data
1.1
Technical details for:
Fig. A
Cable entries (KLE)
Pressure screw
Intermediate gland
AT
EX
EU
y t -
pe e
ATEX type examination certificate:
Marking acc. to 2014/34/EU and standard:
>5 mm
Marking acc. to 2014/34/EU and standard:
Ø
I
E
C
x E
y t
pe e
x
am
IECEx type examination certificate:
M12, M16 (Ø < 9 mm), M20 ... M63
Category of application:
Category of application:
0 mm
(A)
Ø
(A)
The EU-Type Examination Cert t ificate and any future supplements thereto shall, at the same time, be regarded as supplemen
The EC-Type Examination Certificate and any future supplements thereto shall, at the same time, be regarded as supplements to
Cert t ificates PTB 99 ATEX 3128 X and PTB 99 ATEX 3101 X
r
the EC-Type Examination Certificates PTB 99 ATEX 3128 X and PTB 99 ATEX 3101 X
M16 (Ø > 9 mm)
P
er
m
s .
or t
age t
e
m
Perm. storage temperature in original packing:
Degree of protection to IEC/EN 60529:
Degree of protection to IEC/EN 60529:
* ) M40, M50 und M63 with suitable flange seal
)
*
M40, M50 und M63 with suitable flange seal
Type
SW
M12x1,5
15 mm
M16x1,5
20 mm
M20x1,5
24 mm
M25x1,5
29 mm
M32x1,5
36 mm
M40x1,5
46 mm
M50x1,5
55 mm
M63x1,5
68 mm
operating
impact
Type
tempera-
Cable diameter
resistance
ture
1 2
3
Seal 1+2+3
Seal 1+2
min.
max.
min.
(1)(2)
°C
Joule
Ø
Nm
Ø
Nm
Ø
**
**
M12x1,5 -20 - 70 4
M16x1,5 -20 - 70 4
5,5
M20x1,5 -20 - 70 7
5,5
1,5
7,0
1,0
7,0
M20x1,5 -40 - 70 4
5,5
1,5
7,0
1,0
7,0
M25x1,5 -20 - 70 7
8,0
1,5
10,0
2,0
10,0
M25x1,5 -55 - 70 7
8,0
1,5
10,0
2,0
10,0
M32x1,5 -20 - 70 7
14,0
M32x1,5 -55 - 70 7
14,0
M40x1,5 -55 - 70 7
19,0
M50x1,5 -55 - 70 7
24,0
M63x1,5 -55 - 70 7
29,0
41,0 13,0
additional seal
**
Test torques at 20°C
(1)
The tests of clamping ranges and torque values were performed with metal mandrel. The clamping range can vary by using cables with different manufacturing tolerances
and material properties. Please use the combination of sealing 1 + 2 + 3 for the intermediate region.
(2)
When selecting the seal rubber, ensure that the cap nut can be tightened when carrying out any future maintenance work on the cable entry.
Fig. B
Cable diameter 9 mm
Fig. C
Cable diameter 12 mm
e.g. for M25x1,5
e.g. for M25x1,5
seal
seal
seal
seal
1
seal
1
2
3
1
2
3
1
1+2+3
use seal 1 + 2 + 3.
Ø 9 mm
Use seal 1 + 2.
Remove seal 3.
Edition August 2018
Copyright
M12x1,5 to M63x1,5
(
A)
a x
i m
nat
i
on
c
er
i t
c i f
at
e:
P
T
B
14
AT
EX
10
15
X
(A)
PTB 14 ATEX 1015 X
EN
600
79
0 -
EN
600
79
0
II
2
G
Ex
e
I b
C I
G
b
EN 60079-0
II
2
G
E
I b
C I
G
b
II 2 G Ex e IIC Gb
II 2 D Ex tb IIIC Db
II 2 D Ex tb IIIC Db
(A
)
i
na
i t
on
c
er
i f i t
a c
e: t
I
ECE
x
PT
B
14.
0027X
(A)
IECEx PTB 14.0027X
IEC60079-0
Ex eb IIC Gb
IEC60079-0
Ex e IIC Gb
Ex
b t
II
IC
D
b
Ex tb IIIC Db
r
nts to the EC-Type Examination
P
per
at
ur
e i
n or
gi i
nal
pac
i k
ng
:
-
20°
C
bi
s
+
70°
C
-20° C
to
+70° C
IP 66* ) (when fully assemb
bled)
)
IP 66
*
(when fully assembled)
weight
L1
L2
E
app.
19,3 mm
12
/
8 mm
16,2 mm
3,4
23,0 mm
12
/
8 mm
22,0 mm
6,5
25,0 mm
13
/
8 mm
26,5 mm
10,1 g
29,5 mm
13
/
8 mm
32,0 mm
16,9 g
35,5 mm
15
/
10 mm
40,0 mm
27,6 g
39,5 mm
15
/
10 mm
50,5 mm
50,3 g
44,0 mm
16
/
12 mm
60,0 mm
75,9 g
47,0 mm
16
/
12 mm
75,0 mm
117,6 g
Screw-in
thread in
enclosure
1 2
1
Seal 1
max.
min.
max.
(1)(2)
(2)
Nm
Ø
Nm
Ø
Nm
Ø
Nm
Nm
**
**
**
**
**
5,0
0,8
7,0
1,0
1,2
1,0
7,0
1,0
7,0
1,0
10,0
1,4
3,3
1,5
9,0
1,4
9,5
1,0
13,0
1,7
2,7
1,5
9,0
1,4
9,5
1,0
11,0
1,7
2,7
2,3
13,0
2,6
13,5 1,3
17,5
2,3
3,0
2,3
13,0
2,6
13,5 1,5
15,0
2,3
3,0
3,0
17,0
4,0
17,5
1,5
21,0
1,3
5,0
3,0
17,0
4,0
17,5
1,5
21,0
1,3
5,0
3,3
22,0
5,5
22,0 3,3
28,0
6,7
7,5
6,0
28,0
7,0
28,0 5,0
35,0
7,0
7,5
12,0
35,0
12,0
36,0 12,0
41,0
13,0
7,5
48,0
7,8
Fig. D
Cable diameter 16 mm
e.g. for M25x1,5
2
seal
3
seal
1
seal
2
seal
3
2
3
2
3
1+2
1
Ø 12 mm
Use seal 1.
Ø 16 mm
Remove seal 2 + 3.
thuba Ltd., CH-4002 Basel
14
Manual BVS 18 ATEX E 058
g
g
Colour of
dust
protection
cover
white
white
white
green
white
green
white
green
green
green
green
1
Edition August 2018
Switzerland
Copyright
EU-Konformitätserklärung
Déclaration UE de conformité
EU-Declaration of conformity
BVS 18 ATEX E 058
Wir / Nous / We,
thuba AG
PO Box 4460
CH-4002 Basel
Switzerland
erklären in alleiniger Verantwortung, dass die
Explosionsgeschützte Reinraumsteckdose
Prises de courants antidéflagrantes pour salle
déclarons de notre seule responsabilité que les
blanche
Explosionproof clean room power outlet
bearing sole responsibility, hereby declare that the
Typ / type CRS . . .. ...
den grundlegenden Sicherheits- und Gesundheitsschutzanforderungen nach Anhang II der untenstehenden
Richtlinie entspricht.
répond aux exigences essentielles en ce qui concerne la sécurité et la santé fondamentales selon l'annexe II des
directives suivantes.
satisfies the fundamental health and safety protection requirements according to Annex II of the directive named below.
Bestimmungen der Richtlinie
Titel und/oder Nummer sowie Ausgabedatum der Normen
Désignation de la directive
Titre et/ou No. ainsi que date d'émission des normes
Provisions of the directive
Title and/or No. and date of issue of the standards
2014/34/EU: Geräte und Schutzsysteme zur
EN 60079-0:2012-08+A11:2013
bestimmungsgemässen Verwendung in
EN 60079-1:2014-10
explosionsgefährdeten Bereichen
EN 60079-7:2015-12
EN 60079-31:2014-07
2014/34/UE: Appareils et systèmes de protection
EN 60079-14:2014-03
destinés à être utilisés en atmosphère explosible
EN 60079-17:2014-03
2014/34/EU: Equipment and protective systems
EN 60309-1:1999+A1:2007
intended for use in potentially explosive atmospheres
EN 60309-2:1999+A1:2007+A2:2012
EN 60309-4:2007+A1:2012
EN 60529:1991-10+A1:2000+A2:2013
2014/30/EU: Elektromagnetische Verträglichkeit
EN 60947-1:2007-07+A1:2011-01+A2:2014-11
2014/30/UE: Compatibilité électromagnétique
2014/30/EU: Electromagnetic compatibility
2011/65/EU: RoHS Richtlinie
EN 50581:2012
2011/65/UE: Directive RoHS
2011/65/EU: RoHS Directive
Folgende benannte Stelle hat das Konformitätsbewertungsver-
DEKRA EXAM GmbH
fahren nach der Richtlinie 2014/34/EU Anhang III durchgeführt:
0158
L'organe reconnu ci-après a procédé à l'évaluation de la conformité
Dinnendahlstrasse 9
prescrite par la directive 2014/34/UE de l'annexe III:
DE44809 Bochum
The following notified body has carried out the conformity assess-
ment procedure according to Directive 2014/34/EU, Annex III:
Folgende benannte Stelle hat die Bewertung des Moduls
DEKRA EXAM GmbH
«Qualitätssicherung Produktion» nach der Richtlinie
0158
2014/34/EU Anhang IV durchgeführt:
Dinnendahlstrasse 9
L'organe reconnu ci-après a procédé à l'évaluation de la conformité
DE44809 Bochum
prescrite par la directive 2014/34/UE de l'annexe IV:
The following notified body has carried out the conformity assess-
ment procedure according to Directive 2014/34/EU, Annex IV:
Basel, 20. August 2018
Peter Thurnherr
Ort und Datum
Geschäftsführender Inhaber, Elektroingenieur FH
Lieu et date
Administrateur délégué, ingénieur HES
Place and date
Managing Proprietor, B. Sc. Electrical Engineer
15
thuba Ltd., CH-4002 Basel
Switzerland