Connections
Terminal A/B = Data interface SI - RS 485
A, B, C, D
Terminal C = Output supply voltage - GND
Terminal D = Output supply voltage + 24 V DC
Operating voltage
2, 3
Terminal 2 = + 24 V DC
Terminal 3 = -- GND
External unlocking signal.
4
If +24 V DC is supplied to this terminal for ≥1 sec., then an opening cycle is performed in both modes of operation.
Wiring allocation
0
1
4
7
+
-
Set Day/Night adjustment
Switchover between Day and Night mode
Day mode: E opening function, door is not locked
Night mode: Automatic locking when door closes
Adjust magnetic sensor manually (only necessary if the multi-point lock does not lock when the
door is closed)
Blue or
white
Magenta
1x
8 sec
Flashes
Flashes
Turquoise/White
Turquoise/Red
3x
1 sec
Manual activation via the lever handle or the cylinder lock only in case of shutdown of the motor of the
GENIUS 2.1 PANIC multi-point lock as the locking process would otherwise be interrupted.
01.2018
Cable
Band
detection
colour
0
black
1
brown
4
yellow
7
violet
--/3
blue
+/2
red
white
1 x
1 sec
Magenta
5x
1 sec
Flashes
Turquoise/Red
1x
3 sec
KFV
Function
Cable
colour
grey
Switching between Day/Night mode of operation
yellow
Switching between Day/Night mode of operation
green
External unlocking signal
pink
Indicating door/lock status
brown
Operating voltage (--) negative
white
Operating voltage (+) 24 V DC
blue
Day mode
White LED
LED lights up white
LED lights up blue
Turquoise
Turquoise
1x
3 sec
Blue
EN
Function
Shield
Night mode
Blue LED
Press button just once
Flashes
Turquoise/White
7