Tightness inspection
Hoses check
Figure 12
Check that hoses "A" and "B" are in good condition and
correctly fixed.
If the hoses are damaged, broken or badly connected to the
unions, they must be replaced.
Cover tightness check
Figure 13
The cover and liquid container gaskets must be replaced if
they are torn, cut, etc.
Vacuum cleaner disposal
Figure 19
Dispose of the vacuum cleaner in compliance with the laws
in force.
-
Proper disposal (electric and electronic waste)
(applicable in the European Union and in countries
providing a separate collection system)
The symbol shown in the figure is present on the product or
in its documentation and it indicates that the product cannot
be disposed of together with other domestic waste at the end
of its life cycle.
To prevent damages to the environment or the health caused
by improper waste disposal, please separate this product
from other waste and recycle it responsibly in order to
support the sustainable reuse of material resources.
Domestic users should contact the retailer or the local office
providing information on separate collection and recycling of
this product.
Companies should contact the supplier and check the
purchase contract terms and conditions.
This product can not be disposed of together with other
commercial waste.
01/2015
Wiring diagrams
Fig. 14 - 15 - ECO OIL 13 = 230 V / 50-60 Hz.
Fig. 16 - 17 - ECO OIL 22 = 230 V - 400 V / 50 Hz.
Wiring diagram list - fig. 14 - 15
Name
Part
PM
Start button
PA
Stop button
S1
Pump start switch
F1-F2
Fuse holder
M1
Suction motor
M2
Pump
Wiring diagram list - fig. 16 - 17
Name
Part
PM
Start button
PA
Stop button
S1
Pump start switch
F1-F2
Fuse holder
M1
Suction motor
M2
Pump
-7-
ECO OIL 13/22
Code
4084100945
–
–
Code
4084100946
–
–
GB
C77