5. WIRING

To avoid disturbances and malfunction risks, do not pass the wire from the videophone through the same sheaths
as electric wires.
Caution:
never double wires to increase their size.
a. Connecting the videophone
Use the following wires:
1. Connect the wires following the wiring diagram (fig. 6).
2. To connect the camera, only 2 wires are needed for all functions: ring tone, video image, intercom and opening
controls (door opener and automation).
• Terminal "1" from the screen to terminal "1" on the station.
• Terminal "2" from the screen to terminal "2" on the station.
Important : • For the wiring diagram, please consult the label on the back of the monitor and the back of the station.
b. Connecting to a door opener or electronic lock
Connect directly to terminals 5 and 6 on the back of the station (no polarity to respect).
Note that this function is only valid if the screen is switched on. A humming sound may be heard when the control is used.
Important : The door opener or electronic lock you are about to install must have a mechanical memory like
all EXTEL references. For the wiring, please consult the label on the back of the station.
c. Connecting to a motorised entrance gate
Connect directly to terminals 3 and 4 on the back of the station. The outside station delivers a "dry" contact with
no current, to be connected to the "push button control" of your automatic opener.
Note that this function is only valid if the screen is switched on. A humming sound may be heard when the control is used.
d. Connecting an extra camera
Use the following wires: • 2 6 /10 th wires up to 25 m • 2 1.5 mm² wires from 25 to 100 m
1. Connect the wires following the wiring diagram (fig. 6).
2. When connecting the camera there is no need to respect polarity.
3. The outside station and camera wires must be connected together.
e. Connecting an extra camera
Use the following wires: 2 x 1.5 mm² wires
Maximum distance enters the 2 monitors : 25m
Maximum distance between the intercom panel and the last monitor : 100m
1. Connect the wires following the wiring diagram (fig. 6).
2. When connecting the camera there is no need to respect polarity.
IMPORTANT: not to use a principal monitor (master) like secondary monitor (slave)

6. USER GUIDE

a. General
Brush the screen to turn it on. When the monitor
is powered on, the home screen is displayed.
1. Date in the mm-dd-year format
2. Time
3. "Videophone" tab
4. "Recorded visitor" tab
5. "Settings" tab
The SD card must be inserted when the monitor is switched off in order to be taken into account
(fig. 6)
• 2 6 /10 th wires up to 25 m • 2 1.5 mm
CFI EXTEL STEP - STEP ACCESS - 03/2017
2
from 25 to 100 m
1
2
3
4
5
GB4