Instructions for use for the user
9.5. Starting combi mode
1. Use the temperature selector
► The temperature selector
in the temperature display
2. Press the temperature selector
► The sauna heater is switched on and begins to heat up.
► Then the current temperature in the sauna room is displayed in the
temperature display
is displayed.
3. Use the humidity selector
► The humidity selector
in the humidity display
4. Press the humidity selector
► The evaporator switches on.
► Then the current temperature in the sauna room is displayed in the hu-
midity display
preset humidity is displayed.
If the sauna control unit is used without a humidity temperature sensor
(FTS2), cycle mode is activated. If the sauna room temperature is less
than 30 °C, the evaporator is activated continuously for 10 minutes. This
ensures that the water in the tank reaches a basic temperature level.
Cycle mode then starts.
The evaporator can only be started when the sauna heater is switched
on. The maximum humidity level which can be set depends on the tem-
perature of the sauna. The higher the sauna temperature, the lower the
maximum humidity level which can be set.
Exception: Evaporator single mode is activated (see 8.4. Activating
evaporator single mode on page 25). The evaporator can also be
operated here without the sauna heater, with the maximum humidity
depending on the current sauna room temperature.
to set the preferred temperature.
3
flashes and the preset temperature is shown
3
.
4
.
3
. In single-sensor mode, the preset temperature
4
to set the preferred humidity.
2
flashes and the preset temperature is shown
2
.
1
.
2
. If a humidity temperature sensor is not installed, the
1
p. 29/38
EN