Electrical Requirement - Gree GTHCA-K6DNA1A/I Mode D'emploi

Climatiseur de type sol ou plafond
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Item
Model
GTH(09)CA-K6DNA1A/I
GTH(12)CA-K6DNA1A/I
GTH(18)CA-K6DNA1A/I
GTH(24)CB-K6DNA2A/I
(1). The connecting pipe should be thermally insulated properly.
(2). The pipe wall thickness shall be 0.5-1.0 mm and the pipe wall shall be able
to withstand the pressure of 6.0 MPa. The longer the connecting pipe, the
lower the cooling and heating effect performs.
(3). The pipe wall thickness shall be 0.5-1.0mm and the pipe wall shall be able
to withstand the pressure of 6.0 MPa. The longer the connecting pipe, the
lower the cooling and heating effect performs.

4.4 Electrical Requirement

Electric Wire Size and Fuse Capacity.
Indoor Units
9~24k
Notes:
①. The fuse is located on the main board.
②. Install the disconnect device with a contact gap of at least 3 mm in all poles
nearby the units (Both indoor unit and outdoor unit).The appliance must be
positioned so that the plug is accessible.
The specifications of the power cable listed in the Table above
③.
are determined based on the maximum power (maximum amps) of the unit.
The specifications of the power cable listed in the Table above are applied to
④.
the conduit-guarded multi-wire copper cable (like, YJV copper cable,
consisting of PE insulated wires and a PVC cable jacket) used at 40°С and
resistible to 90°С(see IEC 60364-5-52). If the working condition changes, they
should be modified according to the related national standard.
Size of Fitting Pipe(Inch)
Liquid
Gas
1/4
3/8
1/4
1/2
1/4
1/2
3/8
5/8
Power Supply
V/Ph/Hz
220-240V~
50Hz
Table 2
Max. Height
Max.
Pipe
between Indoor
Length
Unit and Outdoor
(m)
20
20
20
20
Table 3
Fuse
Capacity
A
5
12
Floor Ceiling Type Unit
Indoor unit
Drainage
Difference
pipe(Outer
Diameter ×
wall thickness)
Unit (m)
10
Φ17×1.75
10
Φ17×1.75
10
Φ17×1.75
10
Φ17×1.75
Min. Power
Supply Cord
2
mm
0.75
(mm)