Release scroll down button to select menu
Example of setting
LCD shut off if no activity for 3 minutes.
l
6. Operation
Battery charge
The UPS charges the battery as soon as it is connected to the AC outlet, whether button
6 is pressed or not. When used for the first time, the battery will only provide its
maximum performance after it has been charged for 8 hours. It is recommended that
the UPS be permanently connected to the AC power supply to ensure the best possible
performance.
Switching-on the UPS
Press button 6 for about 1 second.
Surge protection outlets 18 without battery backup
Equipment connected to these outlets is supplied as soon as the AC cord 21
in. T hey are not affected by button 6 .
Battery backup outlets 19
Equipment connected to these outlets is supplied as soon as button 6 turns green
(see figure E).
These outlets can be turned on even if the UPS is not connected to AC power
(button 6 flashes).