AC-power disturbance
• I f AC power is disturbed or fails, the UPS continues to operate on battery power.
Button 6 flashes green. In normal mode, the audible alarm beeps every ten seconds,
then every three seconds when the end of battery backup time is near. In silent mode,
the audible alarm simply beeps once when the UPS transfers to battery power.
• I f the power outage lasts longer than the battery backup time, the UPS shuts down
and automatically restarts when power is restored. Following a complete discharge, a
few hours are required to recharge the battery back to full backup time.
Surge protection:
All outlets include surge protection.
Shutdown of the battery backup outlets 19
Press button 6 for more than two seconds.
7. Troubleshooting
(For further information, visit the www.powerquality.eaton.com site or contact post-sales support.)
Problem
1
• The battery backup outlets
are not supplied with power.
2
• The connected devices are not
supplied when AC power fails.
3
• AC power is available, but the
UPS operates on battery power.
4
6
• Green button
audible alarm beeps every 3
seconds.
5
• Fault sign
appear on the LCD
12
panel and audible alarm beeps
continuously.
6
• EcoControl outlets keep powered
when main application (Master
outlet) is stopped.
614-06818-01
Diagnostic
19
• Button
• The devices are not connected
to the battery backup outlets
• Circuit breaker
the rear of the UPS, has been
tripped by an overload on the
UPS output.
• The UPS battery backup outlets
flashes and
19
are overloaded.
• A fault has occurred on the UPS.
The battery backup outlets
no longer supplied.
• EcoControl function is not
activated or not properly set.
6
is not lite on.
19
20
, located at
19
are
Solution
6
• Press button
and check that
it turns green.
• Connect the devices to the
.
battery backup outlets
• Disconnect excess equipment
and reset the circuit breaker
by pressing the corresponding
button.
• Disconnect excess equipment
connected to the battery backup
19
outlets
.
• Call post-sales support.
• Activate or set properly
EcoControl function using the
software provided with the
product.
19
.
20
9