5. Calibration - The tool can be put into
calibration mode using the remote control
by pressing the Axis I and Axis II buttons
on the remote controller's keypad
simultaneously for 5 seconds. The tool will
beep three times to indicate the unit is
entered calibration mode.
(See Calibration section for detailed
procedure.)
To exit the calibration mode, press the
keypad calibration axis I and II buttons
simultaneously for three to five seconds,
then release when you hear two beeps,
signaling the exit of calibration mode.
Turn off the tool, and then turn it back on
again to resume normal operation.
6. Laser Detection To turn on the RCR2's
laser receiver-detector function, press the
coarse/fine select button. On startup, the
detection resolution is coarse, with the
beeper on indicated by the icons on LCD
display. Continue pressing the coarse/fine
select button to cycle through the
following options:
Beeper on, Laser detector on, coarse
resolution, laser in rotation
Beeper off, Laser detector on, coarse
resolution, laser in rotation
Beeper on, Laser detector on, fine resolution,
laser in rotation mode
Beeper off, Laser detector on, fine resolution,
laser in rotation mode
Laser detector power off, Laser in spin mode
Locate the laser beam, using the red sensor
panel on the RCR2. As the laser beam is
approached, a single arrow points in the
direction of the beam. The base unit emits
sounds to aid in locating the laser beam:
Beep Sound - Indicates that the laser
receiver-detector is pointed overly high/low
or far to the left/right.
Continuous Tone - Indicates that the
laser receiver-detector is pointed directly
toward the laser beam.
Center the beam by moving the laser
receiver-detector in the direction of the
arrow. When the beam is aligned with the
center of the detector panel, both arrows
on the LCD display are lit and the beep is
continuous, indicating that it is
properly center.
7. To turn off the RCR2, press its power
on/off button. There is a double beep for
confirmation, the LCD display becomes
blank, and the lasers shut off.
-13-