Product Description

The multifunctional safety module UG 6980 provides protection of men
and machines by enabling and disabling a safety circuit. It is used together
with e-stop buttons, safety gates, light curtains with self testing (type 4)
to IEC/EN 61496-1, 2-hand buttons on presses for metal processing and
productions machines with dangerous closing movements (type III C to
EN 574) and safety mats, edges and tape switches. Simply select 1 out of
6 safety functions on rotary switches - ready. This reduces divers types of
safety modules in stock and simplifies your disposition.

Circuit Diagram

13
14
23
24
A1+
A2
ST1
38
S11
S12
S21
S22
13
23
+
K1
K1/K2
K2
14 24
38
M10562
RES
GND
ST2
UG 6980.02

Connection Terminals

Terminal designation
A1 +
A2
13, 14, 23, 24,
43, 44, 53, 54
38
GND
S11, S21
S12, S22, ST1, ST2, RES
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
13
14
23
24
A1+
A2
ST1
38
S11
S12
S21
S22
13
23
43
53
K1
+
K3
K1-K4
K2
K4
14 24
44 54
38
M11127
RES
GND
ST2
43
44
53 54
UG 6980.04
Signal description
DC 24 V
0 V
Forcibly guided NO contacts for
release circuit
Semiconductor monitoring output
Reference potential for
Semiconductor monitoring output
Control output
Control input
Your Advantage
• Adjustable safety functions:
- E-Stop
- Safety gate
- Two-hand control
- Safety mat / Safety edge
- Exclusive or contacts
- Light curtain
• Manual or auto start
• Only one device, different safety functions
• Protection against manipulation by sealable transparent cover
Features
• According to
- Performance Level (PL) e and category 4 to EN ISO 13849-1
- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061
- Safety Integrity Level (SIL) 3 to IEC/EN 61508 and IEC/EN 61511
• Acc. to EN 50156-1 for furnaces
• Line fault detection on On-button:
• Manual restart or automatic restart
• With or without cross fault monitoring
• 2-channel
• Forcibly guided output contacts
• Output: max. 4 NO instantaneous semiconductor monitoring output
• LED indicator for operation, safety function and failure
• As option with pluggable terminal blocks for easy exchange of devices
- With screw terminals
- Or with cage clamp terminals
• Width: 22.5 mm

Approvals and Markings

Application

Protection of people and machines
• Emergency stop circuits on machines
• Monitoring of position switches on a safety gate
• Switch gear (FSD) for light bars with selftest (type 4) according to
IEC/EN 61496-1
• 2-hand controls for presses as well as other production machinery
with dangerous closing action (Type III C to EN 574)
• Switch gear for safety mats, safety edges and tape switches with a
max. switching current of 15 mA.

Indicators

Green LED ON:
Red LED ERR:
Green LED K1/K2 (.02)
e.g. K1-K4 (.04):
15
Canada / USA
On, when supply connected
On, at internal error
Flashes at external error
On, when relay K1 and K2 (.02)
energized, e.g. when relay
K1, K2, K3 and K4 (.04) energized
Flashes at external error
(see flashing codes)
UG 6980 / 08.07.19 en / 214A