Safety Technique
SAFEMASTER STS/K
Safety switch- and key interlock system
Actuator module K/K
Product Description
Actuator modules K/K is assembled together with other modules into an
STS/K unit and used in connection with an actuator. The actuator modules
are then always part of the STS/K unit and connected with the stationary
part of a separating guard while the actuator is mounted to the movable part
of a separating guard. The actuator modules can be installed in 4 positions
on the STS/K unit, each turned by 90°.
In hostile ambient conditions stainless steel SAFEMASTER STS/K units
have to be used!
ATTENTION !
Mechanical function modules can be installed above and/
!
or below the key module!
Electrical modules can only be installed below the key
module!
Installation Examples
YRXK01M/K
RXK01M/K
All technical data in this list relate to the state at the moment of edition. We reserve the right for
technical improvements and changes at any time.
STS/K-System Benefits
• EU-Test certificate according to the directive 2006/42/EG, annex IX
• For safety applications up to PLe/Cat. 4 according to DIN EN/ISO 13849-1
• Modular and expandable system
• Rugged stainless steel and plastic design
• Wireless mechanical safeguarding
• Easy installation through comprehensive accessories
• Protection against lock-in
• Coding level low, medium, high according to DIN EN ISO 14119:2014-03
Features
• Actuator module with an insertion opening
• Module expansions possible below and above the module
• Can be coded
• Choice of direction in 4 increments of 90°
• Module with (compared to actuator models B/K) inverted function
• Especially suited for difficult installation positions or additional actuator
• This module is also available in stainless steel
Approvals and Markings
Design and Operation
The actuator module K/K offers the option of inverting SAFEMASTER STS/K
functions. Externally, it is identical to the actuator module B/K, but it has an
inverse direction of action. This feature allows for an inverse structure of
STS/K units with other monitoring functions. Standard STS/K units and
inverse functional units can be combined in a key transfer system without
any problem.
Example for inverting a function
With the mechanical interlock M10BM/K the unlocking of the actuator in
the actuator module B/K takes place by the introduction of the matching
key into the key module 10/K. The actuator module is then positioned
above the key module.
The MK01M/K unit has the same functionality. However, with this unit the
actuator module K/K with inverting function is located below the key module
01/K. For some local conditions this design sequence may be beneficial.
M10K01M/K
9
monitoring
SAFEMASTER STS/K Actuator module K / 08.09.20 en / 288A