5.2

EQUIPMENT HOOK-UP

5.2.1

ELECTRICAL CONNECTION

The oven is not provided with power supply cable. When connecting the
appliance electrically, an automatic RCD must be interposed with an
opening distance between contacts of at least 3 mm.
appliance electrically it is essential to procede in the following way:
remove the right side panel;
connect to the terminal block the power cable.
The power supply cable must be of H07-RNF type, with approved
minimum cross section as prescribed by the specific directive.
The electrical outlet must be easy to access, no moving should be
necessary.
!
The electrical connection (plug) must be easily accessible, also
following oven installation.
The distance between the machine and the socket must be adequate to
not cause tension in the power supply cable. In addition, the cable must
not be located beneath the machine support base.
!
If the electrical power supply cable is damaged, it must be
replaced by the technical assistance service or by a qualified
technician to prevent any risks.